Relative Humidity - Temperature - Carbon Dioxide Data Logger Kit
Record and log relative humidity, temperature & CO2 readings and graph data on your PC
Features & Applications
Poor air quality cannot only affect ambient air, but result in decay or damage to a structure. Equipped with infrared technology to accurately measure these components. Measure RH, temperature and CO2 with precision-enabling you to assess the conditions in the test area.
Designed for residential and commercial applications, it also has the ability to calculate and display cfm/person ventilation rate-hence identifying ventilation-related problems such as moisture build-up, combustion gas build-up, etc. Record your findings on your computer utilizing the included graphical software and cable.
Features:
- Dual beam absorption infrared
- Display: LCD
- Sample method: diffusion or flow through (50 – 100 ml/min)
- Power supply: 4 AA batteries (not included) or 6V DC from external AC/DC adapter (included)
- Includes graphing software & computer cable
Applications:
- Commercial
- Residential
Procedure for using the Hobo datalogger:
- Connect the 7001 to channel 3 or 4
- Connect the datalogger to the computer
- Start the Hobo Boxcar software
- Click on the 'Launch' button to connect to the datalogger
- When the Launch screen appears, click on the 'Enable/Disable Channels' button
- Select the appropriate channel (3 or 4) that the 7001 is connected to
- On the pull down menu next to the appropriate channel, select 'Voltage (Cable 2.5 Stereo)'
- Click on the 'Apply' button
Spec Summary:
| Temperature (internal sensor) | |
Range: |
-4 to +158°F (-20 to +70°C) Range for internal sensor when used outside of case: -40 to +248°F (-40 to +120°C) |
Accuracy: |
±1.27°F (±0.7°C) at +70°F |
Resolution: |
0.7°F (0.4°C) at +70°F |
Response time still in air: |
15 min. typical with sensor inside case; 1 min. typical with sensor outside case |
| Relative humidity (user-replaceable RH sensor) | |
Range: |
25 to 95% RH at +80°F for intervals of > 10 seconds, non-condensing and non-fogging |
Accuracy: |
±5% |
Response time: |
10 min. typical in air |
Sensor operating environment: |
+41 to +122°F (+5 to +50°C) non-condensing and non-fogging |
| Power: | |
| External input accepts the following sensors: Wide range of temp sensors (TMCx-Hx series) Split-core CTs for AC current (5 Models) 4-20 mA input cable (CABLE-4-20mA) 0-2.5 V DC input cable (Cable-2.5-Stereo) |
|
Input range: |
0 to +2.5 Volts DC |
Resolution: |
10 mV (8-bit) |
| External 2.5 Volt input 2.5 mm jack: external input ground, input, switched 2.5 Volt output; external input ground connection is not the same as PC interface connection ground and should not be connected to any external ground |
|
Accuracy: |
±10 mV ±1% of reading |
Out power: |
+2.5 Volts DC at 2 mA, active only during measurements |
| Performance | |
| CO2 Channel | |
Measurement Range: |
0-4,000 PPM voltage output 0-10,000 PPM display |
Resolution: |
±1 ppm |
Accuracy: |
±50 ppm or ±5% of reading (up to 1.5% or 15,000 ppm), whichever is greater |
Warm-Up Time: |
<60 seconds at 72°F |
Operating Conditions: |
32-122°F 0-95% RH, non-condensing |
Storage Temperatures: |
-40 to 140°F |
Calibration Interval: |
12 months, offset adjustment using single gas at 0-1000 ppm CO2. |